The plain conclusion first: finishing Phase 1 and Phase 2 tells you what is in the ground. It does not tell you what the land may be used for afterwards. If the site obtained its Record of Site Condition (RSC) through a risk assessment, the Ministry may also have issued a Certificate of Property Use (CPU). That certificate carries long-term obligations for the owner and can prohibit specified uses outright. If you discover it only after closing, the price is already set and the drawings are already drawn — everything costs more to fix from there.

This article covers three things: where a CPU comes from, what it actually imposes, and what buyers, sellers and landlords each need to check.

1. A CPU comes from one route only — an accepted risk assessment

Part XV.1 of Ontario's Environmental Protection Act governs the assessment and cleanup of brownfields and the filing of RSCs. Changing an industrial or commercial property to a more sensitive use, such as residential, usually requires an RSC first. There are two routes to one: clean the soil and groundwater down to the generic standards, or complete a risk assessment — instead of cleaning to the generic standards, you demonstrate that the risk is acceptable under specified management measures.

A CPU arises only on the second route. Under s. 168.6(1), once a Director has accepted a risk assessment under s. 168.5(1)(a), the Director may issue a CPU to the owner. In other words: finding contamination does not create a CPU, and the cleanup-to-standard route usually has none. The risk-assessment route often saves cleanup cost up front, and the price of that saving is frequently the long-term obligations written into a CPU. When you ask a seller for documents, do not stop at "is there an RSC?" Ask which route the RSC took.

2. What a CPU imposes: things you must do, and things you must not do

Section 168.6(1) gives the Director two kinds of power. The first is to require the owner to take actions specified in the certificate to prevent, eliminate or ameliorate an adverse effect identified in the risk assessment — the statute names installing equipment, monitoring contaminants, and recording or reporting information. On a real site that commonly means maintaining a cover or barrier system, following an inspection program, managing soil and groundwater, and filing monitoring reports on schedule. But every CPU is written to its own risk assessment; there is no standard checklist, and only the certificate's own text governs.

The second power is harder-edged: the owner must refrain from using the property for a use specified in the certificate, and from constructing a building specified in the certificate.

Two limits matter. Under s. 168.6(2), a CPU cannot require the owner to reduce a contaminant's concentration below the level required by the standards specified in the risk assessment — it cannot be made stricter than the standard that was accepted. Under s. 168.6(3), the Director may amend the certificate, add terms, or revoke it, on the Director's own initiative or on the owner's application. A CPU is not carved in stone, but revocation takes an application and proof; never price land on the assumption that it will simply be lifted later.

One cost is easy to miss: under s. 132(1.1), a Director may require the owner, in the CPU, to provide financial assurance to the Crown, and under s. 133(3), failing to provide it is itself a ground for an order prohibiting or restricting the use of the property. An invented illustration only: if a CPU required $200,000 of financial assurance, that $200,000 is not a fee, but it is capital locked up — it belongs as its own line in your acquisition math.

3. Why it runs with the land: later buyers, occupants, and permits

For buyers: instruments under the Act bind successors and assigns under s. 19, and s. 197 adds a disclosure mechanism. An order related to the property can require a person with an interest, before dealing with the property, to give a copy to every person acquiring an interest; a certificate setting out that requirement may be registered on title, and once registered it is deemed directed to each subsequent interest-holder. A person who was not given the required copy may treat the dealing as voidable. Strictly, what lands on title is the s. 197 certificate, not the CPU itself — but in practice due diligence must search both: the Environmental Site Registry for the RSC, and title for any s. 197 registration.

For tenants and landlords: under s. 168.6(4), where a CPU prohibits a use or a building, the owner must ensure a copy of the prohibition is given to every occupant, the prohibition applies to each occupant who receives a copy, and the owner must ensure every occupant complies. For a landlord this is blunt: if a tenant carries on a prohibited use, it is not "the tenant's problem alone" — the duty to ensure compliance sits with the owner. A lease that says nothing about the CPU, never delivers a copy, and never limits the permitted use leaves that risk on the landlord.

For permits: s. 168.6(6) opens with "Despite any other Act." Where a CPU prohibits a use or a building, no permit, licence, approval or other instrument may be issued under a prescribed provision to authorize that use or that construction. Zoning permission and clean drawings are not enough; if the CPU prohibits it, the municipality cannot issue the building permit. For a buyer planning to redevelop or change the use, this clause is often more dangerous than the cleanup cost.

One protection completes the picture: under s. 168.7, once an RSC is filed, no order may be issued under specified provisions, in respect of contaminants present before the certification date, against the filer, subsequent owners, occupants and others. That protection is the other side of the same bargain as the CPU's obligations — read them together when you assess a site.

Three misunderstandings I hear most often

"Phase 2 found contamination, so there must be a CPU." No. The RSC route sits in between. Cleanup to the generic standards usually produces no CPU; a CPU may be issued only after a risk assessment has been accepted.

"The CPU is the seller's historical document; after closing it has nothing to do with me." It does. The obligations rest on the owner and bind successors and assigns, and they reach occupants through s. 168.6(4). You are buying not only the land but the unfinished monitoring, maintenance and reporting in that certificate.

"Zoning allows my use, so the permit will come eventually." Not necessarily. Section 168.6(6) says "Despite any other Act": for a use the CPU prohibits, the municipality may not issue a permit to authorize it. Land that works on paper but not in law is the most expensive trap in this area.

If you are looking at commercial land with an environmental history, do these six things in order

  1. Check whether an RSC has been filed: search the Environmental Site Registry, and ask the seller for the full RSC.
  2. Ask which route the RSC took — cleanup to standards, or risk assessment — and if it was a risk assessment, obtain the accepted risk assessment as well.
  3. Get the CPU itself and read it line by line: what it requires (equipment, monitoring, reporting frequency), what uses and buildings it prohibits, and whether it demands financial assurance. Convert each item into an annual cost in your numbers.
  4. Have your lawyer search title: is there a s. 197 certificate registered, has the seller given you the CPU copy as the disclosure requirement demands, and is that delivery documented in the closing papers?
  5. If you will lease the property: write the CPU's existence, its prohibitions and the permitted use into the lease, require the tenant to acknowledge receiving a copy in writing, and set out the consequences of breaching a prohibition.
  6. If you plan to redevelop or change the use: before any design work, take the CPU's prohibitions to a municipal pre-consultation and confirm your intended use is not prohibited — then negotiate price and timing.

Trust Professional, Diligent Work. I am Ming Ren. The most expensive lesson in commercial land is usually not what is buried in it, but the certificate sitting on top of it that nobody pulled out and read. Put the RSC and the CPU on the table first — then we can talk about what the land is worth.


This article is general information only, not legal advice and not environmental compliance advice. Every CPU's terms depend on its own risk assessment. Consult an Ontario lawyer and a licensed environmental consultant (Qualified Person) before acting.

Primary sources: Environmental Protection Act, R.S.O. 1990, c. E.19, ss. 19, 132(1.1), 133(3), 168.5, 168.6, 168.7, 197; O. Reg. 153/04 (Records of Site Condition — Part XV.1 of the Act) (Ontario e-Laws, consulted November 2026). The $200,000 financial assurance figure is illustrative only, not a real case.

This article in other languages: 中文فارسی

Want to talk about your home?

You can also call directly, or scan the code to add Ming on WeChat.

Ming’s WeChat QR code
Scan to add on WeChat

Community guides by city

All cities →
☎ Call MingFree Evaluation