The short answer first: whether the windows and guards in a Toronto rental comply is not settled by asking whether something is installed. Window screens apply to every dwelling unit, whatever the building's size. Guard heights and window fall protection, by contrast, depend on which of two size classes your building falls into — three storeys or fewer with a building area of no more than 600 square metres, or everything larger. Pick the wrong class and every number you check afterwards will be wrong too.
First: put your building in the right class
Chapter 629 of the Toronto Municipal Code is the property standards by-law. It applies to all property in Toronto, not only rentals. The two provisions that matter here are section 629-19 (guards) and section 629-21 (exterior openings such as windows).
A building is in the smaller class under subsection 629-19C only if both conditions hold: three or fewer storeys, and a building area of 600 square metres or less. Fail either condition and subsection 629-19D applies, which captures most apartment buildings and larger rental buildings. The class matters because the requirements for the same balcony or the same window sit in different subsections, and an inspector will cite the subsection that matches your building.
Second: a guard is judged on height and on its openings
Three questions run through the guard rules: is a guard required in that spot at all, how tall is it, and how big are its openings?
| Item | Smaller buildings (629-19C) | Larger buildings (629-19D) |
|---|---|---|
| General guard height | At least 1,070 mm | At least 1,070 mm |
| Guards inside a unit | May be as low as 900 mm | Check the specific D-subsection wording |
| Openings in a guard | Must not let a 100 mm sphere pass | The 100 mm sphere is again the key measure, with position-specific variations to check in the text |
| High exterior stairs and landings | Check under the C provisions | Guards at least 1,500 mm where more than 10 m above adjacent ground |
The 100 mm figure is the one most often misread. On a guard it is a ceiling on gap size: any opening — between balusters, or under the bottom rail — that lets a 100 mm sphere through fails, however tall the guard is. The point is child safety.
An invented example, only to show the method: suppose a three-storey building's rear balcony guard measures 1,100 mm, which looks fine, but the bottom rail sits 130 mm above the deck, so a 100 mm sphere rolls straight under it. That one gap fails on its own. When you inspect, bring something 100 mm across and test every opening; do not just measure height. Remember, too, that guards are not only about balconies: porches, decks, landings and stairs can all require one where an open side presents a drop.
Third: screens are universal; window fall protection is not
The screen rule is the simplest in the chapter: under section 629-21B, every window in a dwelling unit that can be opened must be fitted with a screen, and the screen must be kept in good repair, complete and without defects. It applies in both size classes and at every height. A torn mesh, a warped frame or a missing screen is a standards problem, not a cosmetic one.
Window fall protection is narrower. Subsection 629-19D(4) addresses windows in apartment-building units where the window is more than 2,000 mm above grade and the opening part is within 1,500 mm of the floor. Those windows need fall protection — a guard, or a combination that limits the opening to 100 mm together with the prescribed heavy-duty screen arrangement. Note the same 100 mm number doing the opposite job: on a guard it caps the gap; on a window it caps how far the window may open.
Another invented example: a high-rise bedroom window with a low sill that a child can reach, opening over a long drop, with no limiter and no guard, is exactly the window this rule is aimed at, and a tenant is entitled to ask the landlord to deal with it. A window in the same unit whose opening part sits above 1,500 mm from the floor may fall outside the subsection. Go window by window; do not judge the whole unit at once.
Finally, the link to provincial law. A landlord's repair duty sits in section 20 of the Residential Tenancies Act, 2006: the landlord must maintain the residential complex in a state that complies with health, safety, housing and maintenance standards. Chapter 629 is one of the most direct measures of those maintenance standards in Toronto. If a window or guard problem is not fixed after written notice to the landlord, a tenant can complain to Toronto property standards enforcement and can also apply to the Landlord and Tenant Board (LTB). Photographs, measurements and a copy of the written notice make either route far stronger.
Common misunderstandings
"A torn screen is too minor to be a repair issue." No. Section 629-21B makes screens an express requirement and requires them to be kept in good repair.
"If the guard is tall enough, nobody checks the gaps." Height and openings are separate requirements. The 100 mm sphere test exists precisely to check gaps.
"A window that only opens a crack is the landlord being difficult." On a low apartment window in the larger class, limiting the opening to 100 mm is one of the lawful fall-protection methods. Do not remove a limiter yourself; ask about other compliant options instead.
"These rules are only for rentals." Chapter 629 applies to all Toronto property. Rentals add a second layer, because the same standards feed into the landlord's repair duty under provincial law.
A sensible inspection order
- Classify the building first: storeys and building area, 629-19C or 629-19D, and write down why.
- Check every openable window: screen present, mesh, frame and hardware in good repair; photograph each one.
- Measure every guard: record actual heights and test openings with a 100 mm gauge rather than writing "OK."
- In the larger class, go window by window for fall protection where the window is over 2,000 mm above grade and opens within 1,500 mm of the floor.
- Give written notice of any problem and keep proof of delivery; if that fails, pursue Toronto property standards enforcement and LTB advice as separate routes.
Ming Ren, Broker, RE/MAX Realtron. Windows and guards look like small items until one measurement flips the conclusion. Get the class and the numbers right first, then talk about the repair.
This article is general information, not legal advice. Whether a specific unit complies depends on the building's facts and the current by-law text; consult an Ontario lawyer or licensed paralegal before acting.
Primary sources: Toronto Municipal Code Chapter 629, Property Standards, ss.629-19 and 629-21 (City of Toronto text, consulted November 2026); Residential Tenancies Act, 2006, s.20 (Ontario e-Laws). The balcony and apartment examples are illustrative and invented.
Frequently asked questions
Is a torn window screen too minor to count as a repair issue?
No. Section 629-21B makes screens an express requirement and requires them to be kept in good repair, so a damaged or missing screen does not meet the standard.
If a guard is tall enough, does anyone check the gaps?
Yes. Height and openings are separate requirements, and the 100 mm sphere test exists precisely to check gaps, so meeting the height does not offset a failed gap test.
Is a window that only opens a crack just the landlord being difficult?
On a low apartment window in the larger building class, limiting the opening to 100 mm is one of the lawful fall-protection methods. Do not remove a limiter yourself; ask about other compliant options instead.
Do these rules apply only to rental properties?
No. Chapter 629 applies to all Toronto property; rentals add a second layer because the same standards feed into the landlord's repair duty under provincial law.