Ming RenBroker · RE/MAX Realtron Realty Inc., Brokerage
☎ 647-779-9186

Law & Policy

Downspout Still Plugged Into the Ground? Toronto Requires Disconnection Citywide, With One Narrow Exemption

By , Broker, RE/MAX Realtron Realty Inc. (About Ming) · Published

Ming Ren · Broker · RE/MAX Realtron Realty Inc., Brokerage

← All articles · Law & Policy · Category guide

I am Ming Ren, a Broker with RE/MAX Realtron.

The conclusion first: if a Toronto downspout is directly or indirectly connected to the City sewer system, it must in principle be disconnected, and that duty falls on every property owner in the city, not only on old houses. The only real exception is a narrow one — disconnection would create a hazardous condition, or is genuinely not technically feasible. Even then, you must first seriously try relocating a downspout, re-grading eavestroughs and correcting lot grading, then apply to the General Manager, who decides in sole discretion, separately for each downspout, and may revoke an exemption when conditions change.

First: where the duty sits, and whom it covers

The rule is in section 681-11 S of Toronto Municipal Code Chapter 681, Sewers. For existing buildings it works by area: in the combined sewer area a downspout may not connect to a combined or storm sewer; in the Basement Flooding Study Areas it may not connect to a storm sewer; and everywhere else it likewise may not connect to a storm sewer. The stages took effect at different times, but today the City's Mandatory Downspout Disconnection page states plainly that it is mandatory for all property owners in Toronto to ensure their downspouts are disconnected from the City's sewer system.

The by-law prohibits permitting or maintaining such a connection. Whether the pipe was connected when the house was built or by a previous owner is therefore no answer for the current owner. On a showing, walk the sides of the house and note whether each downspout ends in an elbow discharging at grade or runs straight into a standpipe in the ground.

New or reconstructed buildings face the stricter rule in section 681-11 S(2), barring roof drainage to sanitary, combined or storm connections alike, and, as noted below, a narrower exemption. Separately, where a roof leader discharges storm water into a sanitary sewer, section 681-11 Q(1) requires disconnection at grade.

Second: after disconnection, the water must stay on your lot

Cutting the pipe is not the whole job. Section 681-11 S(1) ties discharge to the Property Standards rules in Chapter 629: a downspout discharging at grade must outlet no more than 150 millimetres above the ground; water discharged at grade must stay within the lot, must not damage adjacent property, and must not create a hazard on stairs, walkways, streets or boulevards; lot grading must carry surface water away from building walls; and eavestroughs and downspouts themselves must be leak-free, defect-free, unblocked and in good repair.

The City page adds practical points worth following: use a splash pad against erosion; do not run an extension across a walkway or in front of a door where it trips people; watch for winter ice where people walk; and do not discharge directly onto a City sidewalk. Rain barrels should come off for winter so they do not crack, with an extension refitted.

If you do it yourself, the City's key steps are to cut about 23 centimetres above where the downspout meets the sewer connection, taking care the cut piece does not fall in; cap the remaining standpipe against water, debris and animals; then fit an elbow and extension carrying water away from the house and foundation. A City-licensed contractor is the alternative. The City page describes financial assistance for eligible low-income seniors and low-income persons with a disability; confirm eligibility and amounts on the page or through 311 before starting.

A clearly labelled illustrative example: a narrow side yard where a disconnected downspout would pour toward a neighbour's basement window well. That is not yet "cannot disconnect." First ask whether the downspout can move to the front or rear, whether eavestrough grading can send the water to another downspout, and whether lot grading can be corrected. Only if those fail does the exemption discussion begin.

Third: two exemption grounds, and why an exemption is not permanent

Section 681-11 S(6) lets an owner apply to the General Manager where disconnecting a downspout would create a hazardous condition or is not technically feasible. For new or reconstructed buildings only the hazard ground is available. Under S(7), the applicant must supply plans, photographs and other documentation the General Manager requests, and the determination is in the General Manager's sole discretion.

The City page is explicit about the order: first make every effort to disconnect, including relocating one or more downspouts, re-grading eavestroughs, or correcting the slope or grading of the property. The application is the Mandatory Downspout Disconnection Exemption Application, with a property sketch. Review considers relocation options, whether hazards can be mitigated or grading corrected, and compliance with other municipal by-laws and regulations. The decision is notified in writing for each connected downspout.

An approval is not forever. The General Manager reserves the right to revoke an exemption where information provided was misleading or inaccurate, or when property or building conditions change — the City gives major landscaping or a new roof as examples. So when a seller says a downspout "has an exemption," ask for the written decision and check which downspouts it covers; and when you plan a roof or yard project, design the downspout outlet into it rather than assuming an old exemption survives.

Non-compliance is not trivial. Contravention of Chapter 681 is an offence, and section 681-14.1 sets maximum fines on conviction — ceilings, not fixed amounts, differing for individuals and corporations, with daily exposure for continuing offences. More day-to-day is the work order power in section 681-14.2: if required work is not done, the City may do it, charge the responsible person, and add the cost to the tax bill. I do not headline the ceiling figures here because they are easily misread as the fine you would actually face; what matters is any order you receive and its deadline.

Three common misunderstandings

One: "My house is decades old and was built this way, so today's rule does not reach it." It does. The staged area rules address buildings as they stand, and the City's position today is citywide; age and original construction are not an exception.

Two: "The yard is small and the water has nowhere to go, so I just apply for an exemption." The order is reversed. Try relocation, eavestrough re-grading and grading correction first, file the sketch and documents, and accept that the General Manager decides in sole discretion. Inconvenience is not the same as hazard or technical infeasibility.

Three: "Once exempt, the house never has to disconnect." An exemption covers specific downspouts in specific conditions. Inaccurate information or changed roof and landscape conditions can lead to revocation; recheck the written decision before a sale or a major project.

A self-check you can do today, in this order

  1. Walk the house and count every downspout, recording whether each ends in a ground standpipe or an elbow at grade, with photos.
  2. For disconnected ones, check outlet height, whether water runs away from walls, and whether it heads for a neighbour, a window well or a sidewalk.
  3. For connected ones, seriously test relocating the downspout, re-grading eavestroughs and correcting lot grading before choosing DIY or a licensed contractor.
  4. When disconnecting, cut, cap the standpipe, and fit the elbow and extension with erosion protection at the outlet.
  5. Only where hazard or technical infeasibility truly remains, file the exemption application with a property sketch; if buying, obtain any claimed exemption decision and match it downspout by downspout.

Ming Ren, Broker, RE/MAX Realtron. One extra look at the side of the house on a showing can save a long round of explanations and remedial work later.


This article is general information, not legal advice. Lot grading, sewer area and building type affect a specific case; consult an Ontario lawyer or confirm with Toronto 311 before acting.

Primary sources: Toronto Municipal Code Chapter 681, Sewers, s.681-11 S and ss.681-14 to 681-14.2; Chapter 629, Property Standards, ss.629-11, 629-20; City of Toronto Mandatory Downspout Disconnection page (checked November 2026). The narrow side-yard house is illustrative, not a real case.

This article in other languages: 中文فارسی

Want to talk about your home?

You can also call directly, or scan the code to add Ming on WeChat.

Ming’s WeChat QR code
Scan to add on WeChat

Community guides by city

All cities →
☎ Call MingFree Evaluation