Here is the plain answer first: aluminum wiring does not, by itself, make a house unbuyable, and finding it does not automatically mean a full rewire to copper. In Flash 25-18-FL (May 2025), Ontario's Electrical Safety Authority (ESA) states that the Ontario Electrical Safety Code permits aluminum wiring, and that the wiring itself is safe when connections and terminations are made properly with devices approved for aluminum. Two things actually decide the outcome: whether every connection has been done properly, and what your own insurer requires. Both need to be settled before you firm up, not discovered after closing.
First: which homes have it, and where the risk really is
ESA places the issue in homes built from the mid-1960s until the late 1970s. In that period, branch circuits — the wiring in the walls feeding receptacles, switches and fixtures — were often aluminum. Some homes have a mix of aluminum and copper, so you cannot judge the whole house from one run of cable.
The risk is not the length of wire in the wall. It is the terminations. ESA says reported problems have been related to overheating and failure of aluminum wiring terminations, tied to aluminum's tendency to oxidize and its incompatibility with devices designed for copper only. If the original devices are not marked as suitable for aluminum, a connection can deteriorate and overheat — sometimes, ESA warns, without any prior indication.
ESA lists the warning signs: warm cover plates on switches or receptacles, discolouration of switches or receptacles, signs of arcing inside devices, flickering lights, and the smell of hot plastic insulation. If you see any of these, do not open the device yourself; stop and have it checked. And the absence of signs is not an all-clear — ESA specifically says not to wait for signs of overheating before dealing with original devices that are not marked for aluminum.
Keep one distinction straight: the larger aluminum feeders used for services and distribution are still widely used today, including by electrical distribution companies. This article is about interior branch wiring and its terminations, not those feeders.
Second: what ESA accepts — read the markings, not the brand names
Start with an assessment by a Licensed Electrical Contractor (LEC) who knows the special techniques for aluminum wiring. ESA's approach is to open all outlets — receptacles, switches, fixtures, appliance connections and the panelboard — and visually inspect terminations for failure and overheating. Where damage is found, the damaged aluminum conductor is cut back before the repair is made.
There are two accepted routes, and both turn on markings:
| Approach | What is required |
|---|---|
| Replace with devices rated for aluminum | Receptacles rated 20 amps or less must be marked "CO/ALR" or "AL–CU"; receptacles over 20 amps must be marked "AL–CU" or "CU–AL"; switches rated 20 amps or less must be marked "CO/ALR" |
| Add copper pigtails | A short copper wire is connected between the aluminum conductor and a copper-only device, using a wire connector marked "AL–CU" or "CU–AL"; the bond conductor must be pigtailed the same way |
A few hard rules sit behind that table: devices with push-in terminations must not be used with aluminum conductors; aluminum is softer than copper and must not be nicked, cut or crushed during termination; stranded aluminum connections require an appropriate joint compound under Rule 12-118; and if the existing box is too small for the added pigtails and connectors, a surface-mounted extension box may be needed. Those details are exactly why this is LEC work, not a weekend project.
An illustrative example, with invented figures only to show the order of judgment: suppose a 1970s house is found to have aluminum branch wiring, the LEC opens the devices, and most terminations are sound while a handful of original receptacles carry no CO/ALR marking. The work might then be replacing that set of non-compliant devices and re-checking the rest to code — not an automatic full rewire. Scope differs in every house; this example is not a real quote.
Once the work is done, it is inspected by ESA, and the homeowner should obtain a copy of the Certificate of Inspection for their records and for the insurer, if requested.
Third: insurance has no single answer — ask your own insurer
This is where buyers most often get caught. ESA states in the same guidance that many insurers will not provide or renew coverage on these properties unless the wiring is inspected and repaired or replaced as necessary, the work is inspected by ESA, and a copy of the certificate of inspection is provided to the insurer. In some cases, ESA adds, the insurer may require replacement of the aluminum wiring with copper. ESA's instruction is direct: check with your insurance company for their requirements.
So there is no universal checklist. One insurer may accept an LEC assessment plus the ESA certificate; another may require replacement; another may have its own form and deadline. Only the company that will actually insure the home can tell you whether the premium changes or conditions apply. A seller, a REALTOR® or a neighbour saying "once it's fixed, insurance is no problem" is not a promise they can make for an insurer.
Timing matters too. An LEC assessment, the repairs, booking the ESA inspection and receiving the certificate all take time. If the deal is already firm and closing is close when insurance stalls on the wiring, the buyer is the one under pressure. On a home from this era, confirm insurance and start the electrical assessment during the offer or condition period.
Three common misunderstandings
1. "Aluminum wiring was recalled and is illegal." No. ESA lists that as a myth. The Ontario Electrical Safety Code permits aluminum wiring. What matters is whether terminations and devices comply.
2. "Nothing feels warm and there is no smell, so we can leave it." No. ESA says aluminum connections have been known to fail and overheat without prior indications, and it strongly recommends replacing original devices that are not marked for aluminum with properly marked devices, or having copper tails installed, rather than waiting for warning signs.
3. "Any new receptacle will do, or I can just twist copper and aluminum together." No. A replacement device that is copper-only is also non-compliant and must be replaced with a copper/aluminum device. A pigtail joint must use a connector marked "AL–CU" or "CU–AL", and push-in terminations must never be used on aluminum conductors.
If you are looking at a 1960s or 1970s home, I suggest this order
- Confirm the build era and the wiring type. Have the home inspector or an LEC check the panelboard and cable markings, and establish whether the home is all aluminum, a mix, or aluminum only on the service feeder.
- During the offer or condition period, call your insurance broker or insurer and ask, in writing: can this home be insured as-is, what inspection or repairs are required, what document must be provided, and by when?
- Hire an LEC experienced with aluminum wiring to assess the home, opening receptacles, switches, fixtures, appliance connections and the panelboard — not a conclusion about the whole house from one or two devices.
- Hold repairs to the markings: CO/ALR or AL–CU on devices, AL–CU or CU–AL on connectors, and no push-in terminations. Get the scope and method in the written quote.
- Make sure the completed work is inspected by ESA and get the Certificate of Inspection. Keep a copy and provide one to the insurer as they require.
- Keep the LEC report, the certificate and the insurer's confirmation on file. When you later sell, that package is your evidence the home was dealt with to code.
Honest work, done properly. I am Ming Ren — if you run into aluminum wiring, do not panic and do not wave it away either. Confirm the insurance first, then have a licensed contractor check every connection, and we will go through the documents one by one.
This article is general information, not electrical or insurance advice. The condition of the wiring in a specific home and your insurer's underwriting requirements will affect the conclusion; consult a Licensed Electrical Contractor and confirm with your insurer before acting.
Primary source: Electrical Safety Authority Flash 25-18-FL, "Aluminum wiring in residential installations" (May 2025, superseding 22-30-FL), and Ontario Electrical Safety Code Rule 12-118 as cited in it (reviewed November 2026). The illustrative scenario above is for explanation only and is not a real transaction or quote.
Frequently asked questions
Was aluminum wiring recalled and is it illegal?
No. ESA lists that as a myth. The Ontario Electrical Safety Code permits aluminum wiring; what matters is whether terminations and devices comply.
Nothing feels warm and there is no smell, so can aluminum wiring be left alone?
No. ESA says aluminum connections have been known to fail and overheat without prior indications, and it strongly recommends replacing original devices not marked for aluminum with properly marked devices, or having copper tails installed.
Will any new receptacle do, or can copper and aluminum just be twisted together?
No. A replacement device that is copper-only is also non-compliant and must be replaced with a copper/aluminum device. A pigtail joint must use a connector marked AL–CU or CU–AL, and push-in terminations must never be used on aluminum conductors.