I am Ming Ren, a Broker with RE/MAX Realtron.
The plain conclusion first: no Ontario statute says in so many words that a commercial office building must be tested for radon, and you will not automatically receive a radon ticket for not testing. That does not mean there is nothing to do. If your workers spend their days in ground-contact, low-floor space, the employer's general duty under the Occupational Health and Safety Act (OHSA) is already engaged. Testing is not the act the law names, but it is often the most direct evidence that you took reasonable precautions. The yardstick for deciding whether to act is Health Canada's guideline of 200 Bq/m³.
This piece stays on the commercial and office side: who should test, where to test, how landlord and employer divide the work, and what happens after a high result.
1. The law does not name radon — that does not erase the employer's duty
Section 25(2)(h) of the OHSA requires an employer to "take every precaution reasonable in the circumstances for the protection of a worker." The clause does not contain the word radon, but its scope was never meant to work by naming hazards one by one: once a known hazard is present, the employer has to assess it and deal with it.
Ontario's own workplace radon guidance follows the same logic. Radon is a naturally occurring radioactive gas, and inhaling it increases the risk of lung cancer. Ontario currently has no radon-specific exposure regulation for general indoor workplaces; the specialized rules for underground mines do not apply to an ordinary office building. For an office, what does the work is the general duty above, with Health Canada's guideline as the benchmark for judging the result.
So get the wording right when you speak to others. You can say: "An employer has a legal duty to take reasonable precautions, and testing for radon is a sound way to meet it." You cannot say: "Ontario law requires every office building to test for radon on a schedule." The first sentence holds up; the second has no basis, and putting it in purchase documents or a lease creates trouble rather than removing it.
2. Test the ground-contact space — not an average of the whole building
Radon enters indoors from the soil and through foundation gaps. It is heavier than air and tends to accumulate on the lowest floor. Ontario's guidance is explicit that levels are generally highest in basements, crawl spaces and other underground environments, with poorly ventilated, confined below-grade space a particular concern. Translated to an office building, the priority locations are below-grade and partially below-grade offices, ground-floor rooms in direct contact with the ground, staff areas on underground levels, and ground-contact mechanical and storage rooms. What matters is where people actually spend time; a precise reading in a corner nobody occupies says nothing about worker exposure.
Do not rush the method. For public buildings, workplaces included, Health Canada recommends a long-term test of at least three months, ideally covering the heating season, because radon levels swing widely with season, heating and ventilation. A reading taken over a few days is a preliminary screen at best, never a conclusion. Use qualified long-term detectors, placed following the public-buildings measurement guide, so the result is a reasonable estimate of the annual average — and only then compare it with 200 Bq/m³.
Here is an illustrative example I made up, with numbers used only to show how to read a result: suppose a ground-contact office returns a long-term annual average of 260 Bq/m³ (illustrative figure, not a real case). That is above 200 Bq/m³, so it should not be waved away as "only a little high" — it belongs in a mitigation plan. If the result were 120 Bq/m³ (also illustrative), it would sit below the guideline: file the report and move on, without panic. What matters is not any single day's number, but the relationship between the long-term average and the guideline.
3. The landlord controls the building, the employer answers for the workers — and the documents decide who pays for mitigation
The argument that stalls commercial properties is who is responsible, landlord or tenant-employer. The division is actually clear. The employer owes the OHSA duty to its own workers and cannot walk away from it because "the building isn't mine." The landlord, as building owner, controls the foundation, the slab and the HVAC system, and structural work cannot be done without the landlord. A tenant generally does not need the landlord's permission to place detectors inside its own leased space, but the results should be shared with the landlord, because the next step usually touches the building itself.
Mitigation starts with the basics: seal obvious entry points and cracks, improve ventilation, and then have a qualified professional assess whether sub-slab depressurization is needed — drawing soil gas out from beneath the slab and venting it outdoors, the most common and reliable approach. Health Canada's recommended timelines are: between 200 and 600 Bq/m³, reduce the level within two years; above 600 Bq/m³, act within one year; in both cases the goal is to get below 200 Bq/m³, and as low as reasonably achievable. Commercial buildings vary enormously in size and foundation, so there is no standard mitigation price — it must be quoted building by building after a site visit, and a residential figure should never be used to estimate an office.
Who pays has no ready-made statutory answer for offices; in the end the lease and the purchase contract decide. Mitigation is in substance a structural, capital improvement to the building, so in negotiation it is usually borne or shared by the owner side — but under a net lease that pushes compliance and improvement costs onto the tenant, the outcome can be different. The same applies on a purchase: for a property with extensive ground-contact office space, put a long-term test into due diligence, and write down in advance who pays for mitigation, or how the price adjusts, if the result comes back high. That is far stronger than discovering it after closing.
Three misunderstandings I hear most often
"There is no law forcing radon testing, so there is nothing to worry about." No. The absence of a named mandate only means the duty does not come from a radon-specific regulation; the general duty in s.25(2)(h) of the OHSA remains. If you know workers spend long hours in ground-contact space, and a guideline and a testing method both exist, doing nothing at all is hard to defend later as a reasonable precaution.
"200 Bq/m³ is a legal limit — 199 is completely safe and 201 is an offence." It is not. The 200 Bq/m³ figure is Health Canada's action guideline, not a penalty line: it means that once the annual average exceeds it, measures should be taken to bring the level down, the lower the better. Below it does not mean zero risk, and above it does not mean an automatic offence. The real question is whether, once you know, you act within a reasonable time.
"A quick test that reads low in a few days clears us." It does not. Radon levels fluctuate too much for a short-term reading to stand in for an annual average. What can support a decision is a long-term test of at least three months, with detectors in the lowest-floor, ground-contact rooms where people actually work. A detector placed in a well-ventilated upper-floor meeting room produces a flattering number and no information.
If your office sits on a low floor, do these five things in order
- Inventory the ground-contact space first: list every below-grade, partially below-grade and ground-floor room where workers spend extended time, and keep the list with the floor plans — it is the basis for detector placement.
- Have a qualified professional run a long-term test, at least three months and ideally covering the heating season, and file the credentials of the devices and laboratory together with the report.
- Read the annual average against 200 Bq/m³: below the guideline, file the result and retest after a major renovation or change of use; above it, schedule mitigation on Health Canada's timelines — within two years for 200–600 Bq/m³, within one year above 600 Bq/m³ — and notify the parties affected in writing.
- If you are a tenant-employer, give the result to the landlord promptly and settle who will do the mitigation work, who pays, and how long it takes — then put what you agreed into a lease amendment or side agreement, not just a conversation.
- If you are buying a commercial property, add radon to the due diligence list: the more ground-contact space, the stronger the case for testing, and the agreement should state in advance who bears mitigation and how the price is handled if levels are high.
Trust Professional, Diligent Work. I am Ming Ren. Radon in an office building is not hard to deal with; the hard part is that nobody wants to test first. Get a number that holds up, and landlord, employer and buyer finally have something concrete to talk about.
This article is general information only, not legal advice. How OHSA duties apply to a specific workplace depends on the use of the space, how long people occupy it, and the terms of the lease. Consult an Ontario lawyer and a qualified radon measurement professional before acting.
Primary sources: Occupational Health and Safety Act, R.S.O. 1990, c. O.1, s.25(2)(h) (Ontario e-Laws); Health Canada, Government of Canada Radon Guideline and Guide for Radon Measurements in Public Buildings; Ontario, Radon in the Workplace (ontario.ca) (all consulted November 2026). The 260 and 120 Bq/m³ figures are illustrative examples, not real cases.