Buying an Industrial Warehouse? Clear Height, Doors and Power Decide Who Can Rent It — Before Price Does

By , Broker, RE/MAX Realtron Realty Inc. (About Ming) · Published

Ming Ren · Broker · RE/MAX Realtron Realty Inc., Brokerage

← All articles · Commercial Real Estate & Leasing · Category guide

I am Ming Ren, a Broker with RE/MAX Realtron.

The plain conclusion: industrial property is one of the few asset types where photographs are nearly useless and the specification sheet decides. Floor area and price are only the entry ticket. What actually decides who can rent the building is how high the clear height is, how many doors of which type it has, how much power it carries, how much load the floor takes, and whether a trailer can manoeuvre in the yard. Miss on any one of these and an entire class of tenants is cut out of your pool — and most of them cannot be fixed, or can be fixed only at a cost that erases the deal. So run industrial due diligence backwards: screen tenants by specification first, estimate rent from the pool that survives, and talk price last.

First: clear height is measured to the lowest obstruction, not to the roof

Clear height is the vertical distance from the floor to the lowest permanent obstruction — the underside of a beam, a sprinkler line, light fixtures, a heating unit, whichever hangs lowest. It is not floor-to-floor height, and it is certainly not the peak of the roof. If the brochure says 32 feet and the sprinkler main hangs at 28, then for a tenant designing racking, this is a 28-foot building.

Why does this rank first? Warehousing is a business that stacks upward. Pallet racking rises level by level, and every additional band of clear height is another full layer of storage over the same footprint — you are buying cubic space without buying another inch of land. A building short on clear height will not even be viewed by distribution and third-party logistics tenants. That is not a price conversation; the racking physically does not fit.

Two cautions when you measure. Clear height varies across the building — it is often lower near the loading area — so measure several points, not the single highest one in the middle. And ask whether the current state is the final state: later sprinkler or mechanical work can eat further into the height. Write the measured figure for each point into your due-diligence notes, not just the number from the brochure.

Second: doors come in two kinds, and the mix is the building's résumé

Industrial doors divide into two types. Dock-high doors open onto a raised dock level with a trailer bed, so a forklift can work straight into the truck — warehousing, distribution and wholesale live on these. Grade-level (drive-in) doors sit flush with the yard, so vehicles can drive into the building — manufacturing, repair, contractors and vehicle businesses need those. How many of each a building has tells you, almost at a glance, whether it was designed for moving goods or for making things. Converting a grade door into a dock door is not adding a door: it means cutting the wall, excavating a dock pit and regrading the yard — a structural project with permits, priced and scheduled like one.

Loading also has a regulatory side. In Toronto, Chapter 220 of Zoning By-law 569-2013 sets hard dimensions for loading spaces: under s.220.5.1(8), a Type A loading space must be at least 17.0 metres long, 3.5 metres wide, with 4.4 metres of vertical clearance; Type B is 11.0 metres long, 3.5 metres wide and 4.0 metres clear; Type C is 6.0 metres long, 3.5 metres wide and 3.0 metres clear. Different uses and floor areas trigger different types and counts. If the site cannot fit the loading spaces the by-law requires, your intended use stalls at approval — however good the building itself is. Other municipalities use different numbers; check the local by-law rather than importing Toronto's.

The same point extends to yard depth: a 53-foot trailer has to turn, drop, and square up to a door. A shallow yard makes extra doors unusable. Distribution tenants touring a building measure the yard before they measure the building.

Third: ask for power in three numbers — and ask whether it can grow

Asking only for amperage is asking nothing. Amps, voltage and phase must come together before you can work out what the building can actually deliver. A pure warehousing tenant uses little — lighting and forklift charging. A manufacturing, plastics, cold-storage or data-type user is in a different order of magnitude, and cold storage compressors are a sustained load, not an occasional peak.

The question that decides value is the next one: can capacity be increased, how long will it take, and who pays? An upgrade runs through the local utility and can involve a new transformer, new service lines or even customer-built distribution facilities. It is measured in months, and its cost can consume the entire discount that attracted you to the building. So insist on evidence: the electrical single-line diagram, a site photo of the main switch nameplate, and written confirmation from the utility — at least two of the three. Never infer capacity from hydro bills. A bill records how much the last tenant used, not how much the building can supply. A warehouse-only predecessor may have used a small fraction of the service for years, and a bill-based conclusion can be wrong in both directions.

The remaining items are invisible but equally hard to change. Floor load is a point-load question: racking legs press tonnes onto tiny footplates, and an older slab that cannot take it must be cut out and repoured. The design load is on the structural drawings — ask for the drawings, not for assurances. Floor flatness matters just as much: on an uneven slab, a high-reach truck will not safely go to the top beam, and you have paid for height you cannot use. Bay spacing decides how racking rows lay out; a column grid that fights the racking module turns aisles into wasted space.

Specification How to verify Who gets screened out
Clear height Measure at several points, to the lowest obstruction Distribution tenants whose racking does not fit
Doors Count dock-high and grade-level separately One of distribution or production
Power Amps × volts × phase, plus utility confirmation Manufacturing, cold storage and other heavy users
Floor and bays Design load and column grid from structural drawings Heavy racking tenants
Yard and loading Measured depth plus local zoning dimensions Trailer operations and use approval

Common misunderstandings

1. "Clear height is the ceiling height — measure to the roof." Clear height stops at the lowest obstruction. Where the sprinkler line hangs is where your height ends; racking does not grow around pipes.

2. "If there are not enough doors, we will add some later." Turning a grade door into a dock door is wall-cutting, pit-digging, regrading structural work, with permits. Budget it as a door and the arithmetic of the deal breaks.

3. "The hydro bills are low, so the power must be sufficient." A bill is usage, not capacity. Capacity comes from the single-line diagram, the nameplate and the utility's written word.

4. "A cheap older building is automatically an opportunity." An older building can be a good buy — if its price already reflects the tenant pool its specifications have cut away. Pricing it on a new building's rent and vacancy is the real trap.

If you are looking at an industrial warehouse, I suggest this order

  1. Measure clear height at several points on site, to the lowest obstruction, and ask whether sprinkler or mechanical changes will reduce it further.
  2. Count dock-high and grade-level doors separately, measure them, and test the yard against your local zoning's loading-space requirements.
  3. Take power as a set: amps, voltage and phase, plus the single-line diagram or a main-switch nameplate photo, and written confirmation from the utility.
  4. Ask the seller for structural drawings and verify floor design load and bay spacing. If drawings do not exist, record the item as unverified — do not guess it.
  5. Work backwards from the verified specifications to the tenant pool: who can use this building, who cannot enter at all — then estimate rent and vacancy from that pool.
  6. Price any upgrade — power, doors, floor work — with real quotes before you offer, and never let a seller's "that is easy to change" into your numbers unverified.

I am Ming Ren. On an industrial building, measure the specifications one by one first — then we can talk about what the building is worth.


This article is general information, not engineering or legal advice. Specifications should be verified by licensed electricians, structural engineers and other qualified professionals; use and loading compliance should be confirmed with the municipal planning department or an Ontario lawyer.

Primary source: City of Toronto Zoning By-law 569-2013, Chapter 220, s.220.5.1(8), loading-space dimensions (Office Consolidation, July 31, 2024; consulted November 2026). Loading standards in other municipalities are governed by their own zoning by-laws.